UKAS Traceable
Calibration
Keynes Controls
utilises only in
house calibration service as part of its manufacturing process for all
of the range of data acquisition products. All the equipment used has
full UKAS trace ability to national standards. The
certificates below show the capability of the calibrator and the date
of the latest calibration by the testing authority. Clients can rest
assured that all our systems are accurately calibrated at the time of
manufacture.
Procedure
Every electronic instrument needs
periodic calibration to compensate for component aging and self heating
effects. Keynes Controls undertakes calibration only after considerable
soak testing to ensure the hardware is operating at its steady state
condition prior to testing. This gives a superior result for
instruments in continuous operation. The company maintains
strict ISO-9000 rules for
calibration operations.
Under Test
The image opposite shows a NetPod
4004 rack system under calibration. Keynes Controls utilise a range of
custom software to carry out the calibration procedure. Samples of test
data can be supplied upon request at the time of manufacture.
In-House
Operations
Keynes Controls only undertake
calibration operations for our own products and are not involved in any
third party operations. Our expertise is concentrated on maintaining
the highest standard for our own systems.
Limited by
50 W output
resistance or
25 mA using
50 W override
Calibration
Certificate Fluke 5100B
Voltage / Current
Calibrator
The main device used for voltage
and current calibration is the Fluke 5100B.
Product Details:
The Fluke 5100B Calibrator is among
the world's leading calibrators for analogue and digital multi meters
to 4.5 digits. The 5100B calibrates precision meters that measure AC or
DC Voltage (0-1100V), AC or
DC current (200 uA-2A), and
Resistance (1 ohm to 10 M Ohms).
Fluke 5100B Accuracies are: DC
voltage and resistance (0.005%), DC current (0.025%) AC Volts (0.05%)
and AC current (0.07%).
UKAS are the sole
accreditation
body recognised by the Government to assess against internationally
recognised standards, laboratories that provide test and calibration
services. UKAS combine a depth of technical knowledge and expertise
built up over many years with scientific and technical specialists
operating across the entire test and calibration spectrum.
(0.05% of output
+ 0.01
mA) RMS
Measured with
10 Hz to 10 KHz
bandwidth
including
random spikes
The tables above show
the technical
capability for voltage and current calibration.
On-line
Calibration Reports
Each system is
supplied with an on-line
calibration certificate. The on-line
records clearly show the period over which the instruments should
operate before a re-calibration
is to be undertaken.
For instruments in continuous use a
calibration period of 1 year is recommended. For systems operating
periodically then re-calibration
after 3 years is possible.
Model: 287 True RMS
Multi-meter
Calibration
Certificate Fluke 287
Vertex V-HV-8
Rotary Table
Keynes Controls calibrate
all the
companies full range of tilt sensors using our UKAS certified Vertex V-HV-8
Rotary Table shown opposite. External calibration can be done on
request but at an extra cost.
Serial No. CDM01.
Select image to
download Calibration
Certificate
Calibration of the In-place-Inclinometers